If your local building authority has a rafter spacing code you may not space rafters wider than required by code.
Roof rafter spacing australia.
For sheet roofed houses with 900 mm rafter spacing in wind classification n4 or c2 the minimum size of f5 or mgp 10 rafters or top chords shall be 90 x 45 mm.
Pitching beams 23 common installation details 25 notches cuts and holes in beams.
Rafters 12 ceiling joists 15 hanging beams member16 underpurlins 17 strutting beams 18 roof beams 20 verandah beams 22 garage roof.
So the space between rafters can be greater without reducing the maximum span.
The closer the rafters are to each other the stronger the roof will be.
Design of single span rafters in roofs in houses office buidlings schools and other structures.
Print full scale rafter plumb cut templates and birdsmouth templates fold template over rafter to mark or cut through.
See rafter run to outer wall calculator below.
2 for design parameters refer to figure 7 26.
This is set by the roof use you selected in the previous screen and cannot be modified.
The same concept holds true for roof trusses.
1 refer to general notes for information that is relevant for all span tables.
The maximum overhang of house rafters or trusses shall not exceed 750 mm from outside of top plate to end of rafter truss.
Half building width minus 1 2 ridge thickness.
A maximum roof pitch of 25 degrees is assumed.
Loads are calculated in accordance with table 3 1 of as nzs 1170 1 2002.
Technical diagram span tables f7 rafters on page 35 30mm m aximum allow able sp ans mm sheet roof spacing mm rafter size 600 760 900 1000 1200 66 x 30 1250 1150 1050 1000 950 90 x 30 1650 1550 1550 1400 1300 138 x 30 2600 2300 2150 2000 1800 185 x 30 3000 2650 2450 2350 2150 230 x 30 3050.
Tables such as those for rafters.
Use these two tables for roof rafters with a slope of 3 in 12 or less.
3 where rafters are equal to or exceed four times their breath blocking should be used to reduce distortion.
If your project had a rafter length of 8 or less a safe and strong method is to use 2x8 framed 16 on center.
Common spacing for trusses on this type of building is often between 2 and 4 feet but trusses built with advanced designs may allow spacing as great as 8 or 12 feet.
Allow for ridge thickness when determining rafter run to outer wall.
As a general rule roofs that have a high human occupancy rate should be framed with rafters every 16 structures such as sheds or barns can be frames with rafters every 24 again make sure to consult local codes.
Wind classification n1 n2.